| Why Didn’t I Think of That...? Pump Alerting Software |
|
|
An Interim Solution to Smart Pump Implementation Incorrectly programmed infusion pumps pose a serious patient safety hazard. Part of the Intermountain Healthcare system, LDS Hospital in Salt Lake City purchased smart pumps to address these safety concerns, but due to hardware and software incompatibilities our smart pump implementation was delayed in the ICUs. Despite the delay in implementation, we determined we needed a system that would quickly alert the health care team when IV infusion pumps are programmed incorrectly. Click here to download the PDF LDS Hospital’s shock trauma respiratory intensive care unit (STRICU) is a 12-bed, level-one ICU. Our multi-disciplinary safety team, made up of approximately 14 members, was given the task of developing a safer method of programming our Alaris model 7132 volumetric infusion pumps for high-risk medications. Interface Development With the help of the medical informatics department, we created a computer program to identify inappropriate dosages and rate changes. Through a review of past event reports and with a query of the top 100 most-used medications in the trauma ICU, we developed a list of 11 high-risk infusions. These medications were assigned acceptable “dosage limits” and acceptable “rates of change” that generate visual alerts on computer screens throughout the ICU. These rates and limits were derived from unit protocols, such as our continuous insulin infusion and heparin protocols, and are based on percent increases over the last running rates. Alerts are also triggered by decimal place errors that occur during pump programming. Solution in Use Each alert also sends an e-mail to the computer programmer and the unit pharmacist, showing the room number, the intended infusion rate and the rate that caused the alert, the pump number, and the medication name. E-mails are also sent with information on overrides, rate corrections, and user names. The nurse and pharmacist from the medication safety team use this information to respond to and evaluate the alerts. Results We were also able to assess why clinicians deviated from specific unit protocols and, subsequently, adjust our alerting limits and educate clinicians on the proper use of the high-risk medications. We have also improved the accuracy of our medication charting. For instance, if a pump had been associated with insulin in the EMAR, but was next used to infuse a vancomycin dose without being re-associated, it would electronically chart an insulin infusion, such as 250 units/hour for one hour. The software’s alerts now prompt the nurse to correct the pump association, thereby maintaining the accuracy of our charts. We also programmed a “keep vein open” (KVO) alert into the software in response to the following patient incident: A patient was on a norepinephrine drip at a high rate, and the bag ran out. The unit was busy, and the audible alert from the pump was not heard. The patient began to decline and additional measures were needed to restore the patient’s blood pressure. Initially, we programmed a KVO alert for all medications, but because it produced too many unneeded alerts, we now include only cardiac medications and propofol. A visual alert is now seen around the unit, and patients’ medication needs can be more quickly taken care of. This enhancement has helped us improve patient safety. The pump alerting system provides sophisticated alerts for many different parameters. Instead of establishing only soft or hard limits, we can alert for percentage increases over the last running rates, tie the alerts into unit protocols, and alert for any piece of data tied to the EMAR. With enhanced alerting, we have created a smart system – not just a smart pump. Clinician approval rates have been high, and we have installed the alerting software in three other ICUs at LDS Hospital, as well as all five ICUs at Intermountain Medical Center. Currently, 22 medications are screened in our alerting database. A patent describing this process and software was filed with the United States Patent and Trademark Office November 8, 2007. Looking Ahead Rick Carlson, PharmD, graduated from Idaho State University and has worked for Intermountain Healthcare for six years. For the past four years, he has served as a critical care clinical pharmacy specialist for the shock trauma ICU. |
| < Prev | Next > |
|---|